Monitoring and preventing excessive hard drive head parking on Linux タリ

It is fairly well-known among techies that hard drives used in server-like workloads can suffer from poor configuration by default such that they frequently load and unload their heads, which can cause disks to fail much faster than they otherwise would. My Seagate Archive SMR disk (which began life as an external hard drive and was retired from that role when it became too small to hold as much as I wanted to back up to it) apparently doesn’t support reporting EPC settings (since asking for them says so), and initially didn’t accept new values for the idle timers either. The Prometheus Node Exporter is the canonical tool for capturing machine metrics like utilization and hardware information with Prometheus, but it alone does not support probing SMART data from storage drives. While SSDs don’t have any heads to park, most do report a media_wearout_indicator that represents the amount of data written to the device in relation to the amount that it’s specified to accept before the Flash storage medium wears out.
Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.

Remote Control LAN Edition

SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.

Can I setup automatic connection without a password on AnyDesk?

  • If you do it on a live pool, I’d back up your data first.
  • Yeah, it’s not helping, thanks.
  • Replacing the drive is financially out of the question.
  • Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.
  • As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.
  • FreeBSD supports a number of different ways to label the disk, depending on your use case.

I noticed that even when doing nothing, I hear the sound of drives working every few seconds. I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent. I guess it depends on the drives, but don’t think you’ll find any software solution. My Seagate Exos enterprise drives make almost 0 noise actually. The system is never idle really, it’s a server. What causes the constant load on the disk?
Obligatory word of warning – mucking with low-level drive settings like this can cause issues. Has anyone found a tool that can use EPC to change the Idle_b and Idle_c values for Exos drives? View an ad to download for free It’s self-hosted and self-managed, so data remains within your company network.Bank-Level EncryptionBanking-standard TLS 1.2 technology protects your computer from unauthorized access. Unparalleled PerformanceOur proprietary video-codec, DeskRT, compresses image data to reduce bandwidth and latency to a level imperceptible to the human eye. With decades of experience in IT management and later as a writer and tutor, she combines technical knowledge with a passion for clear communication.
While I have been aware of this in my home server as well, it is easy to forget to ensure that disks are not silently killing themselves by cycling the heads. With modern, especially Enterprise grade hard drives being able to have hundreds of thousands of head park operations in their service life, is this really an isssue? With the tools presented here, the reader is well armed to react to failed disks and ensure that the wrong disk isn’t accidentally pulled. However, if a disk has died entirely, or a slot is empty, it might not have a device name. Sesutil can also be used to locate the disk in the physical array.While the SES data tells us that there reveryplay is an 8 TB disk in Slot 06, it does not tell us which slot in the chassis corresponds to 06. Looking at a few items from the output, we can see the device names (/dev/da0 and /dev/da7 respectively) of the disks in Slot00 and Slot07.

  • SES provides a mechanism to query information from the enclosure, including temperature, fan speed, and status of power supplies.
  • Remember, the key is to act quickly and use the right tools for your specific situation.
  • These concepts also apply to other operating systems, but the tools might differ slightly.
  • With the tools presented here, the reader is well armed to react to failed disks and ensure that the wrong disk isn’t accidentally pulled.
  • SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time.
  • These special boards, called SAS Expanders, reduce the total cabling required to provide power and signal pathways to all connected disks.

I moved the system dataset to the boot pool. I don’t move any data, no apps are running, this is a vanilla Scale install so far, yet the HDD is in constant work. 1 SSD to boot and 1 HDD to store data. Agree, I have used SeaChest with good results for this same issue on scale plus drive cache. If you do it on a live pool, I’d back up your data first.

Truenas SCALE Seagate Exos X16 Load Cycling, Heads Parking. Change of Idle_b and Idle_c values

For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.

Verifying settings

Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use

I moved my Scale server into the next room, laundry room, just so it’s out of sight. Replacing the drive is financially out of the question. I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load. Yeah, it’s not helping, thanks. Although it’s empty, so this is probably not the source of the constant HDD noise.
Direct Attached deployments require a bit more hardware and cabling. The NVMe interface is also extensible to allow operating over the network (where it is known as NVMe Over Fabric or NVMe-oF). NVMe on the other hand, supports multiple queues (often 64 queues, but the official specification allows for up to 65,536 queues) allowing for many commands to be run concurrently. While both SATA and SAS allow multiple commands to be issued at once to the device, these commands cannot actually be executed concurrently—instead, they are queued for sequential operation.

How do I connect to an unattended desktop with AnyDesk?

The APM specification dating from 1992 includes some controls for hard drives, allowing a host system to specify the desired performance level of a disk and whether standby is permitted by sending commands to a disk. In addition to the above query types, SES also supports a number of commands, including activating the “locate” and “fault” LEDs if present, and the ability to individually power off drives. The first step is to map out the relationship between the physical chassis where the disks reside, and the logical devices enumerated by the operating system.
This will activate the fault LED for element 9 (Slot 08) on the first SES device. You can avoid any uncertainty by enabling the “locate” or “fault” LED for the drive you mean to replace. This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.

Leave a Reply